Tel: +62 21 4586 0646   |   Fax: +62 21 4586 0645
Email: info@gaiascience.co.id
Life Science
 

      

Nano-volume spectrophotometer

The NanoPhotometer® P-Class is an All-in-One spectrophotometer with proven micro volume (0.3μl) and cuvette performance.

Optimized for quantification and purity assessment of nucleic acid and protein samples, the NanoPhotometer® P-Class brings unmatched performance and features in a flexible, compact, and easy to use spectrophotometer.


The features are

  • Flexibility & mobility: All-in-One Small volume and cuvette capability always standard; Standalone mobile design with large LCD display and available thermal printer for convenient direct printing; Electronic data can be automatically generated in a variety of file formats when connected to a PC; USB flash drive, Bluetooth or SD-Memory capability is available on selected models
  • Detection range: Widest concentration coverage Apply NanoVolume samples directly without dilution; Optical alignment, high linearity, and automatic dilution provide the widest concentration range of dsDNA 2-18,750 ng/µl and protein (BSA) 0.08-543 mg/ml
  • Standardization: Instant Ready Technology™ Optimized Sample Condition Ensure homogeneous samples with built-in low vibration vortexer option for consistent readings and accurate results over the entire life-time
  • Small: 0.3 µl sample volume Compression Technology™ allows for accurate determination of nucleic acids, proteins, and peptides in ultra low sample volumes
  • Fast: 3.5 seconds per reading turn on and instantly measure without lamp warm up time; Full scan capability from 200-950nm in 3.5 sec
  • Accurate: Lifetime accuracy without recalibration,Sealed optics without moving parts or pathlength drift eliminates the need for costly and time consuming recalibrations; Avoid evaporation and sample limitations utilizing the patented Sample Compression Technology™

 

The specifications are

  • Nano-volume feature: Detection range dsDNA: from 2 ng/µl to 18,750 ng/µl, BSA: from 0.08 mg/ml to 543 mg/ml, Absorbance range 0.01 – 1.5 (10 mm equivalent: 0.05 – 375),Minimum sample size 0.3 μl, Path lengths 0.04 mm, 0.1 mm, 0.2 mm, 1 mm and 2 mm, Virtual dilution factors 5, 10, 50, 100 and 250
  • Spectromodule: Wavelength range 190 – 1,100 nm, Wavelength scan range 200 – 950 nm, System start up time Less than 5 seconds, no warm up necessary, Measure time for full scan range     3.5 seconds, Wavelength reproducibility < ± 0.2 nm,Wavelength accuracy ± 2nm, Bandwidth Better than 5nm, Stray light < 0.5% at 220 nm using NaI and 340 nm using NaNO2, Photometric range -0.3 – 2.499 A 0-199% T
   
   
   
 
 
Products
 
News & Events

Visit our booth no E-05 at Lab Indonesia 2016 from 13-15 APRIL 2016

01 April,2016

The EBOLA situation

05 January,2015

Gaia Science Wishes All A Happy & Prosperous New Year 2015~

31 December,2014

Gaia Goes Boldly Into New Markets With Stakeholders & Partners to Seek Success!!

20 October,2014

Exclusive Distributor for Particle Sizing System (PSS) in Indonesia

30 September,2014